Server Technology - Server Technology PRO2 Switched POPS C2XG36TE-YCMFAM66
Link - power distribution unit (rack-mountable) - AC 208 V - 8.6 kW - 3-phase - Ethernet 10/100, RS-232 - input: NEMA L21-30P - output connectors: 36 (24 x IEC 60320 C13, 3 x NEMA 5-20R, 12 x IEC 60320 Cx)
Server Technology
C2XG36TE-YCMFAM66
N/A
N/A
New
Product Description
Additional Details
What's Included
Main Specifications | |
---|---|
Product Description | Server Technology PRO2 Switched POPS C2XG36TE-YCMFAM66 - Link - power distribution unit - 8.6 kW |
Device Type | Power distribution unit - rack-mountable |
Input Wiring | 3-phase |
Input Voltage | AC 208 V |
Output Voltage | AC 208 V |
Power Capacity | 8.6 kW |
Input Connectors | 1 x power NEMA L21-30P |
Output connectors | 24 x power IEC 60320 C13 ¦ 12 x power IEC 60320 Cx ¦ 3 x power NEMA 5-20R |
Networking | Ethernet 10/100, RS-232 |
Remote Management Protocol | Telnet, SNMP 3, SNMP 2c, HTTP, HTTPS, SSH-2, CLI |
Dimensions (WxDxH) | 2.2 in x 2.5 in x 70 in |
Manufacturer Warranty | 2-year warranty |
General | |
Device Type | Power distribution unit - rack-mountable |
Expansion / Connectivity | |
Interfaces | 1 x management (Ethernet) - RJ-45 ¦ 1 x management (RS-232) - RJ-45 ¦ 2 x sensor ¦ 1 x monitoring - RJ-12 |
Manufacturer Warranty | |
Service & Support | Limited warranty - parts and labor - 2 years |
Miscellaneous | |
Features | Vertical orientation, LED display, voltage monitoring, current meter, active power meter, energy meter, power factor meter, Per Input Power Sensing (PIPS), Per Outlet Power Sensing (POPS), measurement per phase, High Density Outlet Technology (HDOT), apparent power meter, crest factor meter |
Compliant Standards | UL 489, cTUVus, FCC Part 15 B 15.109A, UL 60950-1:2007, TLS v1.2, CAN/CSA-C22.2 No. 60950-1-07+A1:2011+A2:2014, ANSI C12.1, FCC Part 15 B 15.107A |
Networking | |
Remote Management Interface | Ethernet 10/100, RS-232 |
Remote Management Protocol | Telnet, SNMP 3, SNMP 2c, HTTP, HTTPS, SSH-2, CLI |
Environmental Parameters | |
Min Operating Temperature | 32 °F |
Max Operating Temperature | 140 °F |
Humidity Range Operating | 8 - 90% (non-condensing) |
Power Device | |
Input Voltage | AC 208 V |
Input Wiring | 3-phase |
Input Connectors | 1 x power NEMA L21-30P |
Power Output Connectors Details | 24 x power IEC 60320 C13 ¦ 12 x power IEC 60320 Cx ¦ 3 x power NEMA 5-20R |
Output Voltage | AC 208 V |
Max Electric Current | 30 A |
Power Capacity | 8.6 kW |
Circuit Protection | Circuit breaker |
Dimensions & Weight | |
Width | 2.2 in |
Depth | 2.5 in |
Height | 70 in |