Server Technology - Server Technology PRO2 Switched PDU C2W36TE-DFME2M99
Master - power distribution unit (rack-mountable) - AC 208 V - 14.4 kW - 3-phase 4 Wire delta - Ethernet 10/100, RS-232 - input: CS8365 - output connectors: 36 (18 x IEC 60320 C13 12A, 18 x IEC 60320 Cx)
Server Technology
C2W36TE-DFME2M99
N/A
N/A
New
Product Description
Additional Details
What's Included
Main Specifications | |
---|---|
Product Description | Server Technology PRO2 Switched PDU C2W36TE-DFME2M99 - Master - power distribution unit - 14.4 kW |
Device Type | Power distribution unit - rack-mountable |
Input Wiring | 3-phase 4 Wire delta |
Input Voltage | AC 208 V |
Power Capacity | 14.4 kW |
Input Connectors | 1 x power CS8365 |
Output connectors | 18 x power IEC 60320 C13 12A 12 A ¦ 18 x power IEC 60320 Cx 16 A |
Networking | Ethernet 10/100, RS-232 |
Remote Management Protocol | Telnet, SNMP 3, SNMP 2c, HTTP, HTTPS, SSH-2, CLI, SFTP, SMTP, TACACS+, RADIUS |
Dimensions (WxDxH) | 2.2 in x 2.5 in x 70 in |
Manufacturer Warranty | 2-year warranty |
General | |
Device Type | Power distribution unit - rack-mountable |
Expansion / Connectivity | |
Interfaces | 1 x management (Gigabit Ethernet) - RJ-45 ¦ 1 x management (RS-232) - RJ-45 ¦ 2 x sensor - RJ-12 ¦ 1 x monitoring - RJ-12 |
Manufacturer Warranty | |
Service & Support | Limited warranty - parts and labor - 2 years |
Miscellaneous | |
Features | LED display, thermal monitoring, voltage monitoring, humidity monitoring, current meter, email alerts support, active power meter, energy meter, power factor meter, Per Input Power Sensing (PIPS), measurement per phase, High Density Outlet Technology (HDOT), locking outlets, power measuring, apparent power meter, crest factor meter, hot-swappable controller, Auto-Flip Current Display, Branch Circuit Protection |
Compliant Standards | EMC, UL 60950-1, IEC 60950-1, WEEE, UL 489, TUV T, RoHS 2011/65/EU, EN 55024:2010, EN 55032:2012, UL 248, ANSI C12.1, EN 60950-1:2006+A11+A1+A12+A2 |
Networking | |
Remote Management Interface | Ethernet 10/100, RS-232 |
Remote Management Protocol | Telnet, SNMP 3, SNMP 2c, HTTP, HTTPS, SSH-2, CLI, SFTP, SMTP, TACACS+, RADIUS |
Environmental Parameters | |
Min Operating Temperature | 32 °F |
Max Operating Temperature | 140 °F |
Humidity Range Operating | 8 - 90% (non-condensing) |
Power Device | |
Input Voltage | AC 208 V |
Input Wiring | 3-phase 4 Wire delta |
Input Connectors | 1 x power CS8365 |
Power Output Connectors Details | 18 x power IEC 60320 C13 12A 12 A ¦ 18 x power IEC 60320 Cx 16 A |
Max Electric Current | 50 A |
Power Capacity | 14.4 kW |
Circuit Protection | Circuit breaker |
Dimensions & Weight | |
Width | 2.2 in |
Depth | 2.5 in |
Height | 70 in |