Top Links
Server Technology - Server Technology PRO2 Switched POPS C2WG48TE-DCMFAM99
Master - power distribution unit (rack-mountable) - AC 208 V - 8.6 kW - 3-phase delta - RS-232, Ethernet 10/100/1000 - input: NEMA L15-30P - output connectors: 48 (30 x IEC 60320 C13, 18 x IEC 60320 Cx)
Server Technology
C2WG48TE-DCMFAM99
N/A
N/A
New
Product Description
Additional Details
What's Included
Main Specifications | |
---|---|
Product Description | Server Technology PRO2 Switched POPS C2WG48TE-DCMFAM99 - Master - power distribution unit - 8.6 kW |
Device Type | Power distribution unit - rack-mountable |
Input Wiring | 3-phase delta |
Input Voltage | AC 208 V |
Output Voltage | AC 208 V |
Power Capacity | 8.6 kW |
Input Connectors | 1 x power NEMA L15-30P |
Output connectors | 30 x power IEC 60320 C13 ¦ 18 x power IEC 60320 Cx |
Networking | RS-232, Ethernet 10/100/1000 |
Remote Management Protocol | Telnet, SNMP 3, SNMP 2c, HTTP, HTTPS, SSH-2, CLI, SFTP, SMTP |
Dimensions (WxDxH) | 2.2 in x 2.5 in x 80 in |
Manufacturer Warranty | 2-year warranty |
General | |
Device Type | Power distribution unit - rack-mountable |
Expansion / Connectivity | |
Interfaces | 1 x management (Gigabit Ethernet) - RJ-45 ¦ 1 x management (RS-232) - RJ-45 ¦ 2 x sensor ¦ 1 x cascading - RJ-12 |
Manufacturer Warranty | |
Service & Support | Limited warranty - parts and labor - 2 years |
Miscellaneous | |
Features | Vertical orientation, LED display, voltage monitoring, current meter, active power meter, energy meter, power factor meter, Per Input Power Sensing (PIPS), Per Outlet Power Sensing (POPS), measurement per phase, High Density Outlet Technology (HDOT), apparent power meter, crest factor meter |
Compliant Standards | UL 489, cTUVus, FCC Part 15 B 15.109A, UL 60950-1:2007, TLS v1.2, CAN/CSA-C22.2 No. 60950-1-07+A1:2011+A2:2014, ANSI C12.1, FCC Part 15 B 15.107A |
Networking | |
Remote Management Interface | RS-232, Ethernet 10/100/1000 |
Remote Management Protocol | Telnet, SNMP 3, SNMP 2c, HTTP, HTTPS, SSH-2, CLI, SFTP, SMTP |
Environmental Parameters | |
Min Operating Temperature | 32 °F |
Max Operating Temperature | 140 °F |
Humidity Range Operating | 8 - 90% (non-condensing) |
Power Device | |
Input Voltage | AC 208 V |
Input Wiring | 3-phase delta |
Input Connectors | 1 x power NEMA L15-30P |
Power Output Connectors Details | 30 x power IEC 60320 C13 ¦ 18 x power IEC 60320 Cx |
Output Voltage | AC 208 V |
Max Electric Current | 30 A |
Power Capacity | 8.6 kW |
Circuit Protection | Circuit breaker |
Dimensions & Weight | |
Width | 2.2 in |
Depth | 2.5 in |
Height | 80 in |