Top Links
Server Technology - Server Technology PRO2 Switched PDU C2W48TE-YQME2M99
Primary - power distribution unit (rack-mountable) - AC 208 V - 17.3 kW - 3-phase WYE (star) - Ethernet 10/100, RS-232 - input: IEC 60309 60A - output connectors: 48 (30 x IEC 60320 C13 12A, 18 x IEC 60320 Cx)
Server Technology
C2W48TE-YQME2M99
N/A
N/A
New
Product Description
Additional Details
What's Included
Main Specifications | |
---|---|
Product Description | Server Technology PRO2 Switched PDU C2W48TE-YQME2M99 - Primary - power distribution unit - 17.3 kW |
Device Type | Power distribution unit - rack-mountable |
Input Wiring | 3-phase WYE (star) |
Input Voltage | AC 208 V |
Power Capacity | 17.3 kW |
Input Connectors | 1 x power IEC 60309 60A |
Output connectors | 30 x power IEC 60320 C13 12A 12 A ¦ 18 x power IEC 60320 Cx 16 A |
Networking | Ethernet 10/100, RS-232 |
Remote Management Protocol | Telnet, SNMP 3, SNMP 2c, HTTP, HTTPS, SSH-2, CLI, SFTP, SMTP, TACACS+, RADIUS |
Dimensions (WxDxH) | 2.2 in x 2.5 in x 80 in |
Manufacturer Warranty | 2-year warranty |
General | |
Device Type | Power distribution unit - rack-mountable |
Expansion / Connectivity | |
Interfaces | 1 x management (Ethernet) - RJ-45 ¦ 1 x management (RS-232) - RJ-45 ¦ 2 x sensor - RJ-12 ¦ 1 x monitoring - RJ-12 |
Manufacturer Warranty | |
Service & Support | Limited warranty - parts and labor - 2 years |
Miscellaneous | |
Features | LED display, thermal monitoring, voltage monitoring, humidity monitoring, current meter, email alerts support, active power meter, energy meter, power factor meter, Per Input Power Sensing (PIPS), measurement per phase, High Density Outlet Technology (HDOT), locking outlets, power measuring, apparent power meter, crest factor meter, hot-swappable controller, Auto-Flip Current Display, Branch Circuit Protection |
Compliant Standards | EMC, UL 60950-1, IEC 60950-1, WEEE, UL 489, TUV T, RoHS 2011/65/EU, EN 55024:2010, EN 55032:2012, UL 248, ANSI C12.1, EN 60950-1:2006+A11+A1+A12+A2 |
Networking | |
Remote Management Interface | Ethernet 10/100, RS-232 |
Remote Management Protocol | Telnet, SNMP 3, SNMP 2c, HTTP, HTTPS, SSH-2, CLI, SFTP, SMTP, TACACS+, RADIUS |
Environmental Parameters | |
Min Operating Temperature | 32 °F |
Max Operating Temperature | 140 °F |
Humidity Range Operating | 8 - 90% (non-condensing) |
Power Device | |
Input Voltage | AC 208 V |
Input Wiring | 3-phase WYE (star) |
Input Connectors | 1 x power IEC 60309 60A |
Power Output Connectors Details | 30 x power IEC 60320 C13 12A 12 A ¦ 18 x power IEC 60320 Cx 16 A |
Max Electric Current | 60 A |
Power Capacity | 17.3 kW |
Circuit Protection | Circuit breaker |
Dimensions & Weight | |
Width | 2.2 in |
Depth | 2.5 in |
Height | 80 in |