- Full Catalog
- Tripp Lite
- Systems
- UPS & Power Devices
-
Tripp Lite 16kVA Smart Online UPS 14.4kW 120V 208/240V N+1 14URM TAA
- Back to Results
Main Specifications
|
---|
Product Description
|
Tripp Lite 16kVA Smart Online UPS 14.4kW 120V 208/240V N+1 14URM TAA - UPS - 14.4 kW - 16000 VA - TAA Compliant
|
Device Type
|
UPS - rack-mountable / external
|
Rack Size
|
19" - 14U
|
Input Wiring
|
1-phase 3 Wire
|
Input Voltage
|
AC 208/240 V
|
Output Voltage
|
AC 120/208/240 V ± 2%
|
Power Capacity
|
14.4 kW / 16000 VA
|
Power Redundancy
|
Yes
|
Input Connectors
|
Hardwire 3-wire
|
Output connectors
|
2 x power NEMA L6-30R ¦ 8 x power IEC 60320 C19 ¦ 8 x power NEMA 5-15/20R ¦ 4 x power NEMA 5-15R
|
Run Time (Up To)
|
5.5 min at full load
|
Networking
|
RS-232, USB
|
Remote Management Protocol
|
SNMP, Telnet, HTTP, SSH
|
TAA Compliant
|
TAA Compliant
|
Manufacturer Warranty
|
2-year warranty
|
General
|
---|
Device Type
|
UPS - rack-mountable / external
|
Height (Rack Units)
|
14U
|
Rack Size
|
19"
|
Expansion / Connectivity
|
---|
Interfaces
|
1 x management (USB) ¦ 1 x management (RS-232) ¦ 1 x EPO (emergency power off)
|
Manufacturer Warranty
|
---|
Service & Support
|
Limited warranty - 2 years
|
Miscellaneous
|
---|
Cables Included
|
USB cable ¦ Serial cable ¦ EPO cable
|
Rack Mounting Kit
|
Included
|
Equipment Protection Value
|
250000 US Dollars
|
Features
|
Audible alarm, LED indicators, noise filtering, overvoltage protection, built-in bypass switch, undervoltage protection, cold-start function, cooling fan, automatic shut down
|
Compliant Standards
|
CSA, UL 1778, RoHS, FCC Part 15 A, IEC 61000-4-5:1995 B
|
TAA Compliant
|
Yes
|
Networking
|
---|
Remote Management Interface
|
RS-232, USB
|
Remote Management Protocol
|
SNMP, Telnet, HTTP, SSH
|
Software / System Requirements
|
---|
Software Included
|
TrippLite PowerAlert
|
Environmental Parameters
|
---|
Min Operating Temperature
|
32 °F
|
Max Operating Temperature
|
104 °F
|
Humidity Range Operating
|
0 - 95% (non-condensing)
|
Sound Emission
|
60 dBA
|
Battery
|
---|
Run Time (Up To)
|
5.5 min at full load ¦ 13.5 min at half load
|
Recharge Time
|
6 hours
|
Power Device
|
---|
UPS Technology
|
On-line
|
Power Redundancy
|
Yes
|
Power Redundancy Scheme
|
N+1
|
Input Voltage
|
AC 208/240 V
|
Input Wiring
|
1-phase 3 Wire
|
Frequency Required
|
50/60 Hz
|
Input Connectors
|
Hardwire 3-wire
|
Power Output Connectors Details
|
2 x power NEMA L6-30R ¦ 8 x power IEC 60320 C19 ¦ 8 x power NEMA 5-15/20R ¦ 4 x power NEMA 5-15R
|
Output Voltage
|
AC 120/208/240 V ± 2%
|
Power Capacity
|
14.4 kW / 16000 VA
|
Power Capacity (of Single Unit)
|
8000 VA
|
Output Waveform
|
Sinewave
|
Surge Suppression
|
Yes
|
Circuit Protection
|
Circuit breaker
|
Power Factor (PF)
|
0.9
|
Dimensions & Weight (Shipping)
|
---|
Shipping Width
|
40.2 in
|
Shipping Depth
|
50.8 in
|
Shipping Height
|
36 in
|
Shipping Weight
|
676.81 lbs
|